Split DC inverter air to water heating&cooling&hot water 3 in one heat pump

NULITE NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Split Air to Water Heat Pump.
  • 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW.
  • 2.Best Selling Market:  Central Europe North & East Europe, North Europe, North America.
  • 3.Ambient Temp of Using:  Minus 25C, highest 55-60C hot Water Output.
  • 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC.
  • 5.Japan *Mitsubishi" Twin Rotor Compressor for DC Inverter Split Air Source Heat Pump.
 
HEAT PUMP TYPE DC Inverter TypeSplit Heat Pump Air to Water Heating Cooling DC INVERTER 10-20KW
MANUFACTURER NULITE NEW ENERGY Group
FACTORY SCALE with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016
HEAT PUMP FUNCTION Radiator, FCU, Floor Heating Cooling & Hot Water
MOQ 10-20 Units(1-2 Sample available with stocks)
EFFICIENCY COP 3.5-4.9 at Ambient 7C-25C
SUITABLE MARKET Minus 25C stable WorkingCentral, North & East Market, North America
  SUITABLE HEATING SPACE          TYPE OF HEAT PUMP                       USING AREA                MODEL NAME DC Inverter Split Heat Pump 10KW              (60-100m2)                   BKDX30-95DC Inverter Split Heat Pump 20KW             (150-200m2)                 BKDX50-200
Heat pump factory
INSTALLING IN EU with more than 8,000 units NULITE NEW ENERGY heat pumps installed in EU market
CONTROLLER SYSTEM Intelligent Control Panel, with multi-defrosting system protection, with five mode chooseable, heating, cooling, hot water,hot water then heating, hot water then cooling
More than 500 units heat pump produced daily in NULITE NEW ENERGY workshops
Item BKDX30-95I/150S BKDX50-200I/150S BKDX50-200I/150S
Rated heating capicity KW 10 20 20
Rated cooling capicity KW 2.7-6.6KW 4.5-11KW 4.5-11KW
Max input power KW 1-3KW 2-5.5KW 2.5-6.6KW
Rated current A 12 20 8
Indoor unit Power supply V/Hz 220V 50Hz/60Hz 220V 50Hz/60Hz 220V 50Hz/60Hz
Outdoor unit Power supply V/Hz 220V 50Hz/60Hz 220V 50Hz/60Hz 380V 50Hz/60Hz
Rated output water temperature °C 45
Max output water temperature °C 60
Water flow m³/h 2.2 3.5 3.5
Refrigeration R410A
Rated of waterproof IPX4 IPX4 IPX4
Prevent leakage protection I class I class I class
Control mode Microcomputer central processor (linear control)
Compressor Form Scroll type Scroll type Scroll type
Quantity 1 1 1
Brand Mitsubishi Twin Rotor DC Inverter
Fan Form internal rotor motor,plastic leaves
Fan power W 90 90*2 90*2
Outdoor unit Net size mm 910*445*977 979×418×1200 979×418×1200
Weight Kg 92 112 120
Nosie level dB(A) ≤54 ≤60 ≤60
Indoor unit Auxilary heater KW 3 3 3
heat exchanger stainless steel plate heat exchanger
Net size mm 410*265*606 500*276*606 500*276*606
Ambient temperature °C (-25℃ --  46℃) (-25℃ --  46℃) (-25℃ --  46℃)
Inlet pipe diameter DN25 DN25 DN25
Outlet pipe diameter DN25 DN25 DN25
Test Conditions Heating  : Ambient temp.7°C/6°C,Water temp.40°C/45°C Cooling:   DB / WB: 35°C/24°C   Water Input:12°C ,Water Output:7°C
Concentrate on Advanced Heat Pump Technology
01.COP up to 4.4 30C/35C working condition The application of EVI technology together with high efficiency heat exchanger can improve the heat exchanging rate and make the COP up to 4.4
02.Ambient Temp -25C Show perfect performance NULITE EVI Series Heat Pumps get perfect performance at ambient temperature -25C to ensure stable running all year round.
03.Highest outlet water temp. 60C Due to outlet water up to 60C, the unit can replace the traditional boilers which are applied to the house heating and domestic hot water
04.Intensive Protections Intensive protections have been added to NULITE NEW ENERGY EVI Air to Water Heat Pump in order to make the units run safely.Protections for high discharging temperature, high vacuum degrees excess current and large temperature difference are reinforced in NE EVI Heat Pump
NULITE NEW ENERGY Heat Pump in ISH 2017 The Germany customers is very satisfied with NULITE NEW ENERGY ASHP factory scale, heat pump quality, and the technology innnovation of EVI DC Inverter high efficiency & Minus 35C stable working solutions
NULITE NEW ENERGY HEAT PUMP in Europe NULITE NEW ENERGY Heat Pump of EVI Split & DC Inverter Split Heat Pump is well sold in Europe and North America market, including US, Canada, Germany, Poland, Ukraine, Russia, Finland, Czech, Slovenia, etc.
NULITE NEW ENERGY EVI Heat Pump at South Pole with Extreme Cold Climate NULITE NEW ENERGY Heat Pump is the official heat pump supplier for the 18th Asian Games and for China North & South Pole Expedition Team.

  • Split DC inverter air to water heating&cooling&hot water 3 in one heat pump Related Video: